Rotary Selector Switches - Miniature (Series A)
- Series A - 15° Indexing
- Series A - 20° Indexing
- Series A - 22° Indexing
- Series A - 30° Indexing
- Series A - 36° Indexing
- Series A - 45° Indexing
- Series A - 60° Indexing
- Series A - 90° Indexing
- Series AA - 15° Indexing
- Series AA - 22° Indexing
- Series AA - 30°, 36°, 45° Indexing
- Series AC - 30°, 36°, 45°, 60°, 90° Indexing
|
Series A - 15° Indexing

Designed to meet or exceed the requirements of MIL-S-3786
Same as and interchangeable with 6-1900 Series
Switches feature totally enclosed, explosion proof, unitized construction.
| No. of Positions |
24 Positions
1 Pole Per Deck
12 Positions
2 Poles Per Deck
8 Positions
3 Poles Per Deck
6 Positions
4 Poles Per Deck
4 Positions
6 Poles Per Deck |
| Electrical Rating: |
Continuous 10 amps at 28 v dc |
| Make and Break: (10,000 cycles) |
5 amps res. 115 v ac
3 amps res. 28 v dc
2 amps ind. 28 v dc
|
| Torque: |
1 thru 5 decks - 5 in. lbs. max.
6 thru 12 decks - 8 in. lbs. max. |
| Altitude: |
to 70,000 feet |
| Temperature Range: |
-65oC to +125oC |
| Length: |
1.00 in. max for 1 deck switch
add .375 in. max. for each additional deck |
| Weight: |
.37 lb. max. for 1 deck switch
add .07 lb. for each additional deck |
| Notes: |
NO. OF POSITIONS:
2-24: 1 Pole per deck
2-12: 2 Poles per deck
2-8: 3 Poles per deck
2-6: 4 Poles per deck
2-4: 6 Poles per deck
NON-SHORTING CONTACTS:
Break before make
SHORTING CONTACTS:
Make before break
1 pole per deck, 24 positions, may have stops or be continuous rotation. All other switches will have stops.
All multi-pole switches will have common terminals identified A, B, C, etc. Add letter "D" to P/N Code for deck identification on single pole construction switches. Letter to be adjacent to common terminals. |
|
|
Series A - 20° Indexing

Designed to meet or exceed the requirements of MIL-S-3786
Same as and interchangeable with 12-1900 Series
Switches feature totally enclosed, explosion proof, unitized construction.
| No. of Positions |
18 Positions
1 Pole Per Deck |
| Electrical Rating: |
Continuous 10 amps at 28 v dc |
| Make and Break: (10,000 cycles) |
5 amps res. 115 v ac
3 amps res. 28 v dc
2 amps ind. 28 v dc
|
| Torque: |
1 thru 5 decks - 5 in. lbs. max.
6 thru 12 decks - 8 in. lbs. max. |
| Altitude: |
to 70,000 feet |
| Temperature Range: |
-65oC to +125oC |
| Length: |
1.00 in. max for 1 deck switch
add .375 in. max. for each additional deck |
| Weight: |
.37 lb. max. for 1 deck switch
add .07 lb. for each additional deck |
| Notes: |
NO. OF POSITIONS:
2-18: 1 Pole per deck
NON-SHORTING CONTACTS:
Break before make
SHORTING CONTACTS:
Make before break
1 pole per deck, 18 positions, may have stops or be continuous rotation. All other switches will have stops.
If deck identification is required, decks will be identified A, B, C, etc. Letter adjacent to common terminals.
|
|
|
Series A - 22° Indexing

Designed to meet or exceed the requirements of MIL-S-3786
Same as and interchangeable with 3-1900 Series
Switches feature totally enclosed, explosion proof, unitized construction.
| No. of Positions |
16 Positions
1 Pole Per Deck
8 Positions
2 Poles Per Deck
4 Positions
4 Poles Per Deck |
| Electrical Rating: |
Continuous 10 amps at 28 v dc |
| Make and Break: (10,000 cycles) |
5 amps res. 115 v ac
3 amps res. 28 v dc
2 amps ind. 28 v dc
|
| Torque: |
1 thru 5 decks - 5 in. lbs. max.
6 thru 12 decks - 8 in. lbs. max. |
| Altitude: |
to 70,000 feet |
| Temperature Range: |
-65oC to +125oC |
| Length: |
1.36 in. max for 1 deck switch
add .375 in. max. for each additional deck |
| Weight: |
.28 lb. max. for 1 deck switch
add .06 lb. for each additional deck |
| Notes: |
All multi-pole switches will have common terminals identified A, B, C, etc. Add letter "D" to P/N Code for deck identification on single pole construction switches. Letter to be adjacent to common terminal.
NON-SHORTING CONTACTS:
Break before make
SHORTING CONTACTS:
Make before break
Adjustable Stop Data:
Switch must be in Position 1 prior to adjusting stops. Remove rear plate. Install the (2) stop pins in desired positions. Replace rear plate. If continuous rotation is required (1 pole/deck only), remove pins and place into side holes for storage.
|
|
|
Series A - 30° Indexing

Designed to meet or exceed the requirements of MIL-S-3786
Same as and interchangeable with 1905 Series
Switches feature totally enclosed, explosion proof, unitized construction.
| No. of Positions |
12 Positions
1 Pole Per Deck
6 Positions
2 Poles Per Deck
4 Positions
3 Poles Per Deck
3 Positions
4 Poles Per Deck
2 Positions
6 Poles Per Deck |
| Electrical Rating: |
Continuous 10 amps at 28 v dc |
| Make and Break: (10,000 cycles) |
2 amps res. 115 v ac
1 amps res. 28 v dc
.5 amps ind. 28 v dc
|
| Torque: |
1 thru 5 decks - 3 in. lbs. max.
6 thru 12 decks - 5 in. lbs. max. |
| Altitude: |
to 70,000 feet |
| Temperature Range: |
-65oC to +125oC |
| Length: |
1.00 in. max for 1 deck switch
add .35 in. max. for each additional deck |
| Weight: |
.12 lb. max. for 1 deck switch
add .03 lb. for each additional deck |
| Notes: |
NO. OF POSITIONS:
2-12: 1 Pole per deck
2-6: 2 Poles per deck
2-4: 3 Poles per deck
2-3: 4 Poles per deck
2-2: 6 Poles per deck
NON-SHORTING CONTACTS:
Break before make
SHORTING CONTACTS:
Make before break
1 pole per deck, 12 positions, may have stops or be continuous rotation. All other switches will have stops.
All multi-pole switches will have common terminals identified A, B, C, etc. Add letter "D" to P/N Code for deck identification on single pole construction switches. Letter to be adjacent to common terminals. |
|
|
Series A - 36° Indexing

Designed to meet or exceed the requirements of MIL-S-3786
Same as and interchangeable with 1900 Series
Switches feature totally enclosed, explosion proof, unitized construction.
| No. of Positions |
10 Positions
1 Pole Per Deck
5 Positions
2 Poles Per Deck |
| Electrical Rating: |
Continuous 10 amps at 28 v dc |
| Make and Break: (10,000 cycles) |
5 amps res. 115 v ac
3 amps res. 28 v dc
2 amps ind. 28 v dc
|
| Torque: |
1 thru 5 decks - 3 in. lbs. max.
6 thru 12 decks - 5 in. lbs. max. |
| Altitude: |
to 70,000 feet |
| Temperature Range: |
-65oC to +125oC |
| Length: |
1.00 in. max for 1 deck switch
add .35 in. max. for each additional deck |
| Weight: |
.12 lb. max. for 1 deck switch
add .03 lb. for each additional deck |
| Notes: |
NO. OF POSITIONS:
2-10: 1 Pole per deck
2-5: 2 Poles per deck
NON-SHORTING CONTACTS:
Break before make
SHORTING CONTACTS:
Make before break
1 pole per deck, 10 positions, may have stops or be continuous rotation. All other switches will have stops.
All multi-pole switches will have common terminals identified A, B, C, etc. Add letter "D" to P/N Code for deck identification on single pole construction switches. Letter to be adjacent to common terminals. |
|
|
Series A - 45° Indexing

Designed to meet or exceed the requirements of MIL-S-3786
Same as and interchangeable with 1906 Series
Switches feature totally enclosed, explosion proof, unitized construction.
| No. of Positions |
8 Positions
1 Pole Per Deck
4 Positions
2 Poles Per Deck |
| Electrical Rating: |
Continuous 10 amps at 28 v dc |
| Make and Break: (10,000 cycles) |
5 amps res. 115 v ac
5 amps res. 28 v dc
2.5 amps ind. 28 v dc
|
| Torque: |
1 thru 5 decks - 4 in. lbs. max.
6 thru 12 decks - 8 in. lbs. max. |
| Altitude: |
to 70,000 feet |
| Temperature Range: |
-65oC to +125oC |
| Length: |
1.06 in. max for 1 deck switch
add .410 in. max. for each additional deck |
| Weight: |
.13 lb. max. for 1 deck switch
add .04 lb. for each additional deck |
| Notes: |
NO. OF POSITIONS:
2-8: 1 Pole per deck
2-4: 2 Poles per deck
NON-SHORTING CONTACTS:
Break before make
SHORTING CONTACTS:
Make before break
1 pole per deck, 8 positions, may have stops or be continuous rotation. All other switches will have stops.
All multi-pole switches will have common terminals identified A, B, C, etc. Add letter "D" to P/N Code for deck identification on single pole construction switches. Letter to be adjacent to common terminals. |
|
|
Series A - 60° Indexing

Designed to meet or exceed the requirements of MIL-S-3786
Same as and interchangeable with 50-1926 Series
Switches feature totally enclosed, explosion proof, unitized construction.
| No. of Positions |
6 Positions
1 Pole Per Deck |
| Electrical Rating: |
Continuous 10 amps at 28 v dc |
| Make and Break: (10,000 cycles) |
5 amps res. 115 v ac
3 amps res. 28 v dc
2 amps ind. 28 v dc
|
| Torque: |
1 thru 5 decks - 4 in. lbs. max.
6 thru 12 decks - 7 in. lbs. max. |
| Altitude: |
to 70,000 feet |
| Temperature Range: |
-65oC to +125oC |
| Length: |
1.03 in. max for 1 deck switch
add .35 in. max. for each additional deck |
| Weight: |
.13 lb. max. for 1 deck switch
add .03 lb. for each additional deck |
| Notes: |
NO. OF POSITIONS:
2-6: 1 Pole per deck
NON-SHORTING CONTACTS:
Break before make
SHORTING CONTACTS:
Make before break
1 pole per deck, 6 positions, may have stops or be continuous rotation. All other switches will have stops.
Add letter "D" to P/N Code for deck identification on single pole construction switches. Letter to be adjacent to common terminals. |
|
|
Series A - 90° Indexing

Designed to meet or exceed the requirements of MIL-S-3786
Same as and interchangeable with 51-1921 Series
Switches feature totally enclosed, explosion proof, unitized construction.
| No. of Positions |
4 Positions
1 Pole Per Deck |
| Electrical Rating: |
Continuous 10 amps at 28 v dc |
| Make and Break: (10,000 cycles) |
5 amps res. 115 v ac
5 amps res. 28 v dc
2 amps ind. 28 v dc
|
| Torque: |
1 thru 5 decks - 4 in. lbs. max.
6 thru 12 decks - 6 in. lbs. max. |
| Altitude: |
to 70,000 feet |
| Temperature Range: |
-65oC to +125oC |
| Length: |
1.06 in. max for 1 deck switch
add .410 in. max. for each additional deck |
| Weight: |
.13 lb. max. for 1 deck switch
add .04 lb. for each additional deck |
| Notes: |
NO. OF POSITIONS:
2-4: 1 Pole per deck
NON-SHORTING CONTACTS:
Break before make
SHORTING CONTACTS:
Make before break
1 pole per deck, 4 positions, may have stops or be continuous rotation. All other switches will have stops.
All multi-pole switches will have common terminals identified A, B, C, etc. Add letter "D" to P/N Code for deck identification on single pole construction switches. Letter to be adjacent to common terminals. |
|
|
Series AA - 15° Indexing

Designed to meet or exceed the requirements of MIL-S-3786
Same as and interchangeable with 6-1900 Series
Switches feature totally enclosed, explosion proof, unitized construction.
| No. of Positions |
24 Positions
1 Pole Per Deck
12 Positions
2 Poles Per Deck
8 Positions
3 Poles Per Deck
6 Positions
4 Poles Per Deck
4 Positions
6 Poles Per Deck |
| Electrical Rating: |
Continuous 10 amps at 28 v dc |
| Make and Break: (10,000 cycles) |
5 amps res. 115 v ac
3 amps res. 28 v dc
2 amps ind. 28 v dc
|
| Torque: |
1 thru 5 decks - 5 in. lbs. max.
6 thru 12 decks - 8 in. lbs. max. |
| Altitude: |
to 70,000 feet |
| Temperature Range: |
-65oC to +125oC |
| Length: |
1.26 in. max for 1 deck switch
add .375 in. max. for each additional deck |
| Weight: |
.39 lb. max. for 1 deck switch
add .07 lb. for each additional deck |
| Notes: |
All multi-pole switches will have common terminals identified A, B, C, etc. Add letter "D" to P/N Code for deck identification on single pole construction switches. Letter to be adjacent to common terminals.
NON-SHORTING CONTACTS:
Break before make
SHORTING CONTACTS:
Make before break
1 pole per deck, 24 positions, may have stops or be continuous rotation. All other switches will have stops.
Adjustable Stop Data: Switch must be in Position 1 prior to adjusting stops. Remove rear plate. Install the (2) stop pins in desired positions. Replace rear plate. If continuous rotation is required (I pole/deck only), remove pins and place into side holes for storage |
|
|
Series AA - 22° Indexing

Designed to meet or exceed the requirements of MIL-S-3786
Same as and interchangeable with 3-1900 Series
Switches feature totally enclosed, explosion proof, unitized construction.
| No. of Positions |
16 Positions
1 Pole Per Deck
8 Positions
2 Poles Per Deck
4 Positions
4 Poles Per Deck |
| Electrical Rating: |
Continuous 10 amps at 28 v dc |
| Make and Break: (10,000 cycles) |
5 amps res. 115 v ac
3 amps res. 28 v dc
2 amps ind. 28 v dc
|
| Torque: |
1 thru 5 decks - 5 in. lbs. max.
6 thru 12 decks - 8 in. lbs. max. |
| Altitude: |
to 70,000 feet |
| Temperature Range: |
-65oC to +125oC |
| Length: |
1.36 in. max for 1 deck switch
add .375 in. max. for each additional deck |
| Weight: |
.28 lb. max. for 1 deck switch
add .06 lb. for each additional deck |
| Notes: |
All multi-pole switches will have common terminals identified A, B, C, etc. Add letter "D" to P/N Code for deck identification on single pole construction switches. Letter to be adjacent to common terminal.
NON-SHORTING CONTACTS:
Break before make
SHORTING CONTACTS:
Make before break
Adjustable Stop Data:
Switch must be in Position 1 prior to adjusting stops. Remove rear plate. Install the (2) stop pins in desired positions. Replace rear plate. If continuous rotation is required (1 pole/deck only), remove pins and place into side holes for storage.
|
|
|
Series AA - 30°, 36°, 45° Indexing

Designed to meet or exceed the requirements of MIL-S-3786
Switches feature totally enclosed, explosion proof, unitized construction.
| No. of Positions |
AA30-1
12 Positions
1 Pole Per Deck
AA30-2
6 Positions
2 Poles Per Deck
AA30-3
4 Positions
3 Poles Per Deck
AA36-1
10 Positions
1 Poles Per Deck
AA36-2
5 Positions
2 Poles Per Deck
AA45-1
8 Positions
1 Pole Per Deck
AA45-2
4 Positions
2 Poles Per Deck |
| |
AA30
(12 Positions) |
AA36
(10 Positions) |
AA45
(8 Positions) |
| Electrical Rating: |
Continuous 10 amps at 28 v dc |
| Make and Break: (10,000 cycles) |
2 amps res. 115 v ac
1 amps res. 28 v dc
.5 amps ind. 28 v dc
|
5 amps res. 115 v ac
3 amps res. 28 v dc
2 amps ind. 28 v dc |
| Torque: |
1 thru 5 decks - 3 in. lbs. max.
6 thru 12 decks - 5 in. lbs. max. |
1 thru 5 decks - 4 in. lbs. max.
6 thru 12 decks - 8 in. lbs. max. |
| Altitude: |
to 70,000 feet |
| Temperature Range: |
-65oC to +125oC |
| Length: |
1.23 in. max for 1 deck switch
add .35 in. max. for each additional deck |
1.29 in. max for 1 deck switch
add .41 in. max. for each additional deck |
| Weight: |
.15 lb. max. for 1 deck switch
add .03 lb. for each additional deck |
.17 lb. max. for 1 deck switch
add .04 lb. for each additional deck |
| Notes: |
Poles/Deck:
30 = 1,2 or 3
36 = 1 or 2
45 = 1 or 2
All multiple switches will have common terminals identified A, B, C etc. Add letter 'D' to P/N code for deck identification on single pole construction switches. Letters to be adjacent to common terminals.
Adjustable Stop Data:
Switch must be in position 1 prior to adjusting stops. Remove rear plate. Install the (2) stop pins in desired positions. Replace rear plate. If continuous rotation is required (1 pole/deck only), remove pins and place into side holes for storage.
|
|
|
Series AC - 30°, 36°, 45°, 60°, 90° Indexing

Designed to meet or exceed the requirements of MIL-S-3786
Switches feature totally enclosed, explosion proof, unitized construction.
| No. of Positions |
AC30
12 Positions
Max. 30° Index
AC36
10 Positions
Max. 36° index
AC45
8 Positions
Max. 45° Index
AC60
6 Positions
Max. 60° Index
AC90
4 Positions
Max 90° Index |
| |
AC60
(6 Positions)
AC36
(10 Positions) |
AC90
(4 Positions)
AC45
(8 Positions) |
AA30
(12 Positions) |
| Electrical Rating: |
Continuous 10 amps at 28 v dc |
| Make and Break: (10,000 cycles) |
5 amps res. 115 v ac
3 amps res. 28 v dc
2 amps ind. 28 v dc
|
5 amps res. 115 v ac
5 amps res. 28 v dc
2.5 amps ind. 28 v dc |
2 amps res. 115 v ac
1 amps res. 28 v dc
.5 amps ind. 28 v dc |
| Altitude: |
to 70,000 feet |
| Temperature Range: |
-65oC to +125oC |
| Notes: |
ROTATION TORQUE:
5 in. lbs. max. for AC30, AC36 and AC45 Units
7 in. lbs. for AC60 Units
6 in. lbs. for AC90 Units
|
|
|
|
|
|
|
|
|
|
|
|